Description
FALCON TEST ENGINEERS REPORT No.: |
3855 | ||||
CONFIGURATION OF PACKAGING: |
|||||
Four Absorbent pads, 4 x vacutainers, swab and sterile container are placed inside the re-sealable bag. Re-sealable bag is placed inside the 850 mL HDPE jar. The void space is filled with shredded paper and the jar is closed. The box is assembled using the self locking system. EPS stabilising inserts are placed around the inside of the box and the jar is inserted into the box. EPS stabilising insert is placed on top of the jar and the top flaps of the fibreboard box are closed and sealed using self locking tab. Add the required amount of absorbent material if specified. Label the box as required.
(Make sure that the labels or any other markings are not obliterated or obscured in any way). Note: The use of other packaging methods or components may render the approval of this package invalid |
|||||
MARKINGS & APPROVAL: |
|||||
Approval No.: |
30433 | ||||
UN Markings: |
UN 4G/CLASS 6.2/**/AUS/30433/HAZPAK | ||||
Packing Group: |
N/A | ||||
S.G.: |
N/A | ||||
Internal Test Pressure: |
180 kPa at Ambient and -95 kPa at +550C and -400C | ||||
PRODUCT DIMENSIONS: |
|||||
Dimensions: |
120 (L) x 120 (W) x 240 (H) mm |
Bulk Equivalent: |
0.9 kg (@ 250 kg/m3) | ||
Nominal Volume: |
Mass of Empty Package: |
260 g |